Communication Manager Maintenance-Object Repair Procedures
646 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Test timed out.
1. If the ATM-TRK circuit pack is in standby, reset the board and run the
test again after the ATM-TRK circuit pack is inserted.
2. Examine the Error Log for Error 1218 (bad DSP).
3. Run the test again.
2100 ABRT Could not allocate required system resources.
1. Retry the command at 1-minute intervals up to 5 times.
2302 ABRT Inconsistent uplink message from the ATM-TRK circuit pack.
2500 ABRT Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2752 ABRT Circuit pack not a TN2305A/2306A.
XYZ FAIL There is at least one bad DSP on the board. The X value indicates the
number of bad talker DSPs, Y indicates the number of bad listener DSPs
and Z indicates the number of bad echo canceler DSPs.
1. Test the Active Tone-Clock in the PN that contains the ATM-TRK circuit
pack for dial-tone. Repair as needed.
2. Repeat the short test on the ATM-TRK circuit pack.
3. If the test continues to fail, check for service-affecting MINOR alarms.
If a MINOR alarm is raised for Error Type 2817 or 1818, replace the
circuit pack.
4. If a WARNING alarm is raised, this is a non-service-affecting error, and
the circuit pack can still process calls.
XYZ PASS The test passed for some or all DSPs. XYZ indicates the number of talker,
listener, and echo-canceler DSPs for which the test passed (the rest of the
DSPs were skipped). The X value indicates the number of good talker
DSPs, Y indicates the number of good listener DSPs, and Z indicates the
number of good echo canceler DSPs.
Table 220: ATM Board DSP Test (#1293) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3