TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005 2305
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
1025 (n) Any None MAJ
MIN
WRN
1
OFF
1281 (m
) Any EPF M and E Lead
(#74)
MAJ
MIN
WRN
1
ON test port location sh r 3
1537 Looparound and
Conference (#33)
MAJ
MIN
WRN
1
ON test port location l r 3
1793 Tie Trunk Seizure
(#73)
Dial Test #747 for
TN439
MAJ
MIN
WRN
1
OFF test port location sh r 2
2049 NPE Crosstalk (#6) MAJ
MIN
WRN
1
ON test port location l r 3
2305 (o
) 57424
50944
None (l)
2561 (p
) 0 None WRN OFF
2562 (q
) 16665
2817 (p
) 0 None MIN OFF
2817 (r
) 52992
3073 (p
) 0 None
3840 (s
) 8000 Transmission tests
(ATMS) (#844–848)
OFF test analog-testcall
3841 (s
) Transmission tests
(ATMS) (#844–848)
MIN OFF test analog-testcall
location r 2
1. Minor alarms on this MO may be downgraded to Warning based on the values used in set
options.
If the MINOR alarm is not downgraded, the MINOR alarm is upgraded to a MAJOR
alarm if 75% of the trunks in this trunk group are alarmed. These errors, if applicable, always
log a MINOR alarm for TN439 and TN497.0
Table 828: TIE Trunk Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2