ISDN-TRK (DS1 ISDN Trunk)
Issue 1 June 2005 1453
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: Disagreement between this switch and the switch at the other end of the
trunk connection with regard to the ISDN call state of the DS1 ISDN Trunk. This switch will
automatically try to recover by clearing the call, (that is, call will be torn down). You can use
status trunk grp#/mem# to determine the state of the trunk.
When running the short test sequence, pay close attention to the results of the Call State
Audit test (#257).
c. Error Type 15: Software audit error and does not indicate a hardware malfunction. Run the
short test sequence, and investigate associated errors.
d. Error Type 19: Possible protocol mismatch or far end may be out of service.
e. Error Type 129: The far-end switch changed its ISDN service state to either out of service
or maintenance. This may be either a temporary condition due to far-end testing of that
trunk or a hardware problem with the trunk. Outgoing calls will not be allowed over the trunk.
To investigate the status of the trunk, enter status trunk grp#/mem#.
513 (h
) Any None WRN OFF test port location
769 (g
)AnyNone test port location
1025 (i
)0 None
1281 Any Conference Circuit
Test (#7)
MAJ
MIN
WRN
1
ON test port location l r 4
1537 Any NPE Crosstalk Test
(#6)
MAJ
MIN
WRN
ON test port location l r 3
1793 (j
)AnyNone test port location
3073 (k
) Any Service State Audit
(#256)
test port location
3585 (l
)AnyNone
3841 (m
) Any None WRN OFF
1. Major or minor alarms may be downgraded to Warning alarms based on the value used in the set
options command.
Table 521: DS1 ISDN Trunk Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2