Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1364 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
IP Address Update Test #1371
This test is destructive.
This test queries the media processor for its IP address, subnet mask, and gateway translation
(IP parameters). If the parameters do not match software translation, maintenance software
reboots the board. The board goes through a logical board removal and insertion.
or:
This test sends the IP Media Resource the IP address, subnet mask, and gateway translation
(IP parameters). If the parameters do not match software translation, the system reboots the
board. The board goes through a logical board removal and insertion.
When this test fails, it is an indication that an illegal change was made and the customer should
be notified.
Table 478: Test #1371 IP Address Query Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Insufficient system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2801 ABRT Unable to find IP address data for this location.
1. Verify that the board is administered.
2807 ABRT The board is administered, but not enabled on the change
ip-interfaces form.
FAIL The IP address, subnet mask, and gateway translation parameters do not
match Communication Manager translations. The board has been reset.
1. If the problem persists, replace the circuit pack.
PASS Translation data matches.