Communication Manager Maintenance-Object Repair Procedures
2362 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The Tone Generator could be defective. In a port network with more than
one IPSI or Tone-Clock circuit pack, the system will attempt to move the
tone generation function to the alternate one.
1. Test the IPSI or Tone-Clock circuit pack again using test
tone-clock location.
2. If the test fails again, look at the Hardware Error Log for Tone Detector
circuit pack errors.
3. If there are Tone Detector circuit pack errors, see Tone Detector
maintenance documentation (DTMR-PT (Dual-Tone Multifrequency
Receiver Port) on page 1115, GPTD-PT (General-Purpose Tone
Detector Port) on page 1308, CLSFY-PT (Call Classifier Port) on
page 811, ETR-PT (Enhanced Tone Receiver Port)
on page 1167 to
resolve these errors first.
4. If there are no Tone Detector circuit pack errors, then the IPSI or
Tone-Clock circuit pack should be replaced. See Replacing the IPSI or
Tone-Clock Circuit Pack on page 2337.
PASS The tone generation facility is able to put tones out.
Table 845: Test #90 Tone Generator Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2