Communication Manager Maintenance-Object Repair Procedures
1532 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Control Channel Loop-Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies its records.
Table 553: Test #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
None
2100
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command up to 5 times.
2. If the problem continues, and if the circuit pack is one of the Port
circuit packs, replace the circuit pack.
3. Otherwise, if the circuit pack is part of the SPE, use the procedure
described in Reseating and replacing circuit packs
in Maintenance
Procedures (03-300192).
PASS Communication with this circuit pack is successful.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute add ds1
location to administer the MAPD interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board re-initializes it.
3. If the board was found to be inserted correctly, enter busyout
board.
4. Enter the reset board command.
5. Enter the release board command.
6. Enter the test board long command.
This should re-establish the linkage between the internal ID and the port.