CLSFY-PT (Call Classifier Port)
Issue 1 June 2005 815
Tone Detector Audit/Update Test (#43)
This test performs a sanity audit on the CLSFY-PT (Call Classifier Port).
Table 280: Test #43 Tone Detector Audit/Update Test
Error
Code
Test
Result
Description / Recommendation
none ABRT The system was not able to allocate the resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Hardware audit failed.
1. Enter these commands in order: busyout board, reset board,
release board. The board reset is required to reload on-board RAM
associated with the TN744’s DSPs. This takes all 8 Tone Detector
ports out of service for a few seconds. Only 4 of the 8 would be out of
service due to the alarm. (There are five Tone Detectors on each of the
two DSPs.) Other than the unlikely potential of running out of Tone
Detector resources in the switch, there is no other effect when the
board is reset.
2. Test the board with test board location long.
3. If the test still fails, replace the board.
PASS The call classifier port has passed the sanity inquiry.