Communication Manager Maintenance-Object Repair Procedures
1704 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Analog Port Sanity Test (#963)
This test verifies that the port circuitry involved in the analog trunk testing on the Maintenance/
Test analog port is functioning properly.
This test will abort if an ATMS test call is in progress on the Maintenance/Test analog port when
the test is requested.
Table 631: Test #963 Analog Port Sanity Test
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals up to 5 times.
50 FAIL The switch was unable to communicate with the port circuitry used for
analog trunk testing.
1. Reset the circuit pack using busyout board location, reset
board location, and release board location.
2. Test the port again using test port location l.
3. If the test fails again, replace the circuit pack.
PASS The Maintenance/Test analog port analog trunk testing capability is
operating correctly.