IPMEDPRO (TN2302 IP Media Processor)
Issue 1 June 2005 1367
MP Diagnostic Test (#1406)
This test is destructive.
The MP Diagnostic test (#1406) runs the following diagnostic tests in the following order, but
only if each successive test passes:
1. DSP FPGA Query
2. ETHERNET Query
3. SCOTCH Sanity
2100 ABRT The necessary system resources to execute the test could not be
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2801 ABRT No IP address defined. Verify IP interfaces translations and retest.
2802 ABRT Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
2805 FAIL The number of pings received did not match the number sent (normally
one ping sent). This means that no ping responses were received from the
gateway defined on the ip-interface form for the media processor.
1. Retry the command at 1-minute intervals up to 3 times.
2807 ABRT The board is administered but not enabled on the change
ip-interfaces form.
7
89
1007
FAIL
A ping to the destination failed through this port. This failure is because the
destination is down.
1. Verify that at least one destination is reachable through this port.
2. Once verified, execute test port location to verify that the H.323
Signaling Group Ping test (#1387) passes.
PASS Ping through this port is successful.
Table 480: Test #1379 Ping Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2