1395 ABRT This test cannot run on an ATM-EI circuit pack if it is part of the B-side
PNC and Duplicated PNC is not enabled.
1. If this test needs to run on this ATM-EI circuit pack, enable PNC with
the change system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the
set PNC lock command.
3. Repeat this test.
1413 ABRT This test requires the use of a Tone-Clock circuit in each of the PNs used
in this test. This abort code indicates that a Tone-Clock circuit is absent
from one of the PNs.
1. Verify that an IPSI or Tone-Clock circuit pack resides in the same PN
as the ATM PNC Expansion Interface circuit pack under test.
2. In ATM PNC configurations, make sure that there is at least one other
PN besides the PN where the ATM-EI circuit pack under test resides
that contains a Tone-Clock circuit.
1414 ABRT The active Tone-Clock circuit in one of the PNs being used for the test has
a MAJOR or MINOR alarm logged against it.
1. Enter display alarms and resolve any TONE-BD and TONE-PT
alarms.
1956 ABRT ACL to the board is not up. See ACL status with list sys-link and
follow the repair procedures for SYS-LINK.
2000 ABRT Response to the test request was not received within the allowable time
period.
2100 ABRT System resources required to run this test are not available.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL The test tone was not detected correctly in either direction.
1. Test the active Tone-Clocks in the PNs for which the ATM-EI circuit
pack under test provides a link. This determines if the dial tone is
supplied.
Table 174: Expansion Interface 2-Way Transmission Test (#241) (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 8