Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005 571
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Verify that at least one Tone Detector resides in this PN. (Even without
a TTR-LEV error, the tested circuit pack’s PN could be missing a Tone
Detector.)
If missing, the test always aborts for this circuit pack, without harming
the system.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 3 times.
1962 ABRT Every DSPs is busy (an unlikely event).
1. Retry the command at 1-minute intervals up to 3 times.
2000 ABRT Response to the test was not received within the allowable time period for
some of the DSPs.
1. If the board is in standby, reset the board and run the test again.
2. Look into the Error Log for Error Type 1218 (bad DSP). If Error Type
1218 is not logged against this board, run the DSP test again and see if
the error persists.
2100 ABRT Could not allocate the necessary system resources to run this test.
2302 ABRT Inconsistent uplink message from the ATM-EI board (an unlikely event).
1. Retry the command at 1-minute intervals up to 3 times.
2500 ABRT Internal system error
2752 ABRT The circuit pack in this location is not a TN230X.
Table 185: ATM Board DSP Test (#1293) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3