DID-TRK (Direct Inward Dial Trunk)
Issue 1 June 2005 903
NPE Crosstalk Test (#6)
Note:
Note: S8300 / G700: This test aborts with Error Code 1412.
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected time slot on
the TDM bus and never crosses over to time slots reserved for other connections. If the NPE is
not working correctly, 1-way and noisy connections may be observed. This test is usually only
part of a port’s long test sequence and executes in about 20 to 30 seconds.
Looparound and Conference Circuit test (#33)
S8300 / G700: This test aborts with Error Code 1412.
XND
Port Audit Update test (#36) X X ND
1. D = Destructive; ND = Nondestructive
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
2 of 2
Table 308: Test #6 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources for this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Enter display port location to determine the station extension,
attendant number, or trunk group/member number of the port. Enter
status station, status attendant, or status trunk to
determine the service state of the port. If the port is in use, wait until it
is idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
2. If the port status is active but the port is idle (no calls), check the Error
Log for Error Type 513. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1 of 3