SIP-SGRP (SIP Signaling Group)
Issue 1 June 2005 1977
MedPro Status Test (#1392)
This test is nondestructive.
This test determines if at least one media processor port exists that is in service, and that
serves the same region as the C-LAN that the signaling group uses. If at least one exists and is
in service, the test passes; otherwise, the test fails.
Table 724: Test #1392 MedPro Status Test
Error
Code
Test
Result
Description / Recommendation
2100 ABRT The necessary system resources to execute the test could not be
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
Any
ABRT Internal system Error.
1. Retry the command at 1-minute intervals up to 3 times
FAIL No MEDPRO ports in this region are in service. Every session is down.
1. Check the system for errors against MEDPRO and MEDPROPT
maintenance objects.
2. Execute test signaling-group grp# and verify the result of the
SIP Signaling Group Ping test (#1387). If the test continues to fail,
escalate the problem. If the test passes, wait for the sessions to come
up.
PASS Every session on the Ethernet link is up.