MMI-PT
Issue 1 June 2005 1673
Table 619: Test #1111 Resource Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Retry the command at 1-minute intervals up to 5 times.
2. Use status conference to determine if there is an active
conference. If a call is active, the test cannot run until the conference
call finishes.
1002 ABRT The system could not allocate time slots for the test. The traffic load on the
system may be very high, or time slots may be out-of-service due to
TDM-Bus errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone detector for the test. The system is
oversized for the number of tone detectors present or some tone detectors
are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
1004 ABRT The resource has been seized by a user for a valid call. Use status
conference to verify that there is an active conference call.
1. If there are no conference calls, retry the command at 1-minute
intervals up to 5 times.
2000 ABRT Response to the test was not received from the Tone Detector circuit pack
within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack, if the other ports
are idle. Reset the circuit pack by issuing busyout board
location and reset board location, followed by release
board location.
2. If this result occurs again, replace the circuit pack.
2012 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2