Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
DIG-LINE (Digital Line)
Issue 1 June 2005 945
1001 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out of service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension or
attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the port is in
use, wait until it is idle before testing. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals up to 5 times.
S8300 /
G700
1412
ABRT This test does not execute on a G700 Media Gateway.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Rerun the test at 1-minute intervals up to 5 times.
7 FAIL Conference test failed on primary channel. In some cases, users may not
notice disruption in service. In extreme cases, conferencing feature may not
work at all.
Table 323: Test #13 Voice and Control Channel Local Loop Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3