Communication Manager Maintenance-Object Repair Procedures
1760 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2020 ABRT The test did not run due to a previously existing error on the specific port
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the previously existing error.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1, 2 FAIL The NPE of the tested port was found to be transmitting in Error Log.
This will cause noisy and unreliable connections. Failure code 1 indicates
that the Crosstalk test failed on the primary channel. Failure code 2
indicates that the Crosstalk test failed on the secondary channel.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this test up
to up to 10 times and verify that it continues to pass.
2. If complaints still exist, examine the data module, connections, and
wiring.
Table 651: Test #9 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3