Communication Manager Maintenance-Object Repair Procedures
1616 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
FAIL The MM710 interface Media Module detected a red alarm. An out of
frame condition occurred on the MM710 interface Media Module. The
MM710 interface Media Module will transmit a yellow alarm to the remote
MM710 endpoint until the red alarm is retired.
If the MM710 connects to a T1 network facility or to another switch, do
the following:
1. Check the physical connectivity of the MM710 packs and of the
cable.
2. Replace the local MM710 interface Media Module, and repeat the
test.
3. Verify that both endpoints of the DS1 link are administered using the
same signaling mode, framing mode, and line coding.
4. Contact T1 Network Service or a technician at the far-end switch to
diagnose the remote DS1 endpoint.
If the MM710 connects to a line-side terminating device (for example, a
PRI terminal adapter), do the following:
1. Check the physical connection of the MM710 interface Media
Module to the terminating device, and check the premise distribution
system (or the intra-premise wiring) for physical connection failures.
2. Replace the local MM710 interface Media Module and repeat the
test.
3. Verify that the switch DS1 and the line-side terminating device are
administered using the same signaling mode, framing mode, and
line coding.
4. Investigate the maintenance status of the line-side terminating
device. Refer to the 'Line-Side Terminating Device Operating
Manual' for information.
5. Contact the vendor of the line-side terminating device to diagnose
the equipment.
Table 594: TEST #140 Red Alarm Inquiry Test (continued)
Error
Code
Test
Result
Description/ Recommendation
2 of 4