Communication Manager Maintenance-Object Repair Procedures
632 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Control Channel Loop Test (#52)
The nondestructive Control Channel Loop test is part of the maintenance subsystem’s Common
Port Board Testing feature. The Common Port Board test sends board vintage queries to a port
circuit pack and checks the responses. CCMS downlink notifications tell the circuit pack which
TDM Bus (A or B) carries the control channel and which carries the touch tones.
PASS The circuit pack has been updated with its translation.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check the board translations.
2. If the ATM-TRK circuit pack is not administered, run add atm trunk
location.
3. If the ATM-TRK circuit pack is administered correctly, check the error
log.
4. If ATM-TRK circuit pack is hyperactive, shut down, and reseat the
circuit pack to force re-initialization.
5. If the ATM-TRK circuit pack is correctly inserted, run busyout board
location
6. Run reset board location
7. Run release board location
8. Run test board location long to re-establish the linkage
between the internal ID and the port.
Table 211: Test #50 Connection Audit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2