Communication Manager Maintenance-Object Repair Procedures
352 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1004 ABRT The port was put in use during the test.
1. Use display port location to determine the voice port extension
of the port. Use status station to determine the service state of the
port. If the service state indicates that the port is active, wait until it is
idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7 FAIL Conference test failed on the primary channel. Some users may notice a
disruption in service. In extreme cases, the conferencing feature may not
work at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
15 FAIL The control channel between the processor and the EMBEDDED AUDIX
circuit pack is not transmitting properly. User impact may range from no
noticeable effect to loss of use of this port.
16 FAIL The secondary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
None FAIL The test failed for reasons external to the EMBEDDED AUDIX circuit pack.
1. Use test board location sh to run circuit tests to check the Tone
Generator circuit and the Tone Detector circuit.
2. Resolve any problems that are detected on the Tone Generator circuit
or Tone Detector circuit.
3. If both circuit packs are functioning properly and the test still fails,
replace the EMBEDDED AUDIX circuit pack (see caution at the
beginning of this section).
PASS Voice and Control Channel Local Loop test passed. Every channel is
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to
10 times, and see whether it continues to pass.
2. If complaints still exist, examine the connections.
Table 95: Test #13 Voice and Control Channel Local Loop Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2