Communication Manager Maintenance-Object Repair Procedures
1694 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
5011 ABRT The Network Control Channel allocated for this test did not disconnect
properly.
1. Follow the repair procedures for Error Code 5001.
5012 ABRT The digital portion of the tested Modem Pool Port did not disconnect
properly.
1. Follow the repair procedures for Error Code 5000.
5013 FAIL The Modem Pool Port did not respond with an on-hook message when
the connection to the Data Channel was broken, indicating a likely
problem with the TN758 Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5014 ABRT The Network Control Channel allocated for this test did not respond
correctly to the setup message sent to it after the connection was
established.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit pack using the
test data-module command (refer to the DATA-CHL maintenance
strategy).
3. If the DATA-CHL circuit pack tests pass, escalate the problem.
5015 ABRT Data Channels 1 and/or 3 have not been administered.
1. Administer the Data Channels and retest.
PASS The port can correctly transmit/receive data.
Table 624: Test #98 Modem Pool Conversion Resource Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
6 of 6