DIOD-TRK (DIOD Trunk)
Issue 1 June 2005 969
1005 ABRT Trunk has been administered as incoming-only; or DID trunk group type; dial
tone can only be obtained on outgoing trunks. This is a normal condition.
S8300
/
G700
1412
ABRT This test does not execute on a G700 Media Gateway.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Trunk was seized, but dial tone could not be detected.
1. Check for errors on TONE-BD or TONE-PT. Clear any errors and
repeat test.
2. If error has still not cleared, refer problem to CO.
2002 FAIL Seizure portion of test failed due to hardware problem. Fault is usually
caused by a disconnected trunk.
1. Check trunk wiring to ensure good connection; repeat test if wiring
correction made.
2. Locate another identical CO trunk and swap its wiring with one under
test. Repeat test on both trunks and determine whether problem follows
trunk or remains at original port. If problem follows trunk, refer problem
to CO. If problem remains at port, replace the circuit pack and repeat
test.
1009 PASS Detected tone was not pure dial tone. No action required.
PASS Trunk was seized, and dial tone was detected. User-reported troubles on this
port should be investigated by using other port tests and by examining trunk
or external wiring.
Table 333: Test #0 Dial Tone Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2