Communication Manager Maintenance-Object Repair Procedures
1072 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
DS1 Interface Options Audit Test (#798)
This test is nondestructive.
This test sends the administered DS1 Interface options to the DS1 converter circuit pack.
Options are sent to both DS1 converter circuit packs at the same time to prevent any
transitional mismatch of options.
The following DS1 facility options are sent to the TN574 DS1 converter circuit pack: Framing
Mode, Line Coding and DS1 converter-1 and DS1 converter-2 Line Compensation.
The following DS1 facility options are sent to the TN1654 DS1 converter circuit pack: Line
Coding and DS1 converter-1 and DS1 converter-2 Line Compensation (T1 only). These option
fields appear on the Fiber-link Administration screen.
Table 366: Test #798 DS1 Interface Options Audit
Error
Code
Test
Result
Description / Recommendation
105 ABRT The neighbor DS1 converter circuit pack at the other end of the DS1
converter complex is not accessible.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2000 ABRT Timed out while waiting for a response from the circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABRT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABRT The timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316 ABRT Fiber link is not administered. Use add fiber-link to administer the
DS1 converter fiber link.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS The DS1 Interface options are sent to the circuit pack.