SNC-BD (Switch Node Clock Circuit Pack)
Issue 1 June 2005 2027
2301 ABRT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2306 ABRT None of the circuit packs in this switch node carrier are responding to the
processor route messages sent by software.
1. Run test led switch-node for the switch node where this switch
node carrier resides to verify whether the LEDs on any of the boards
light.
2. If none of the LEDs light for the boards in this carrier, fix any problems
associated with the connectivity of this carrier to the server.
a. Use list fiber link to obtain a list of the fiber connections to
this carrier.
b. Check the LEDs on every SNI and EI, and fix any fiber problems.
c. Enter display errors, and follow the repair procedures for any
EXP-INTF error entries associated with the controlling IPSI
connected PN.
d. Follow the repair procedures for any SYNC, SNI-BD, SNC-BD,
FIBER-LK, or SNI-PEER error entries.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
Table 740: TEST #760 Processor Route Audit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3