Communication Manager Maintenance-Object Repair Procedures
1940 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
REM-OFF (Remote Office)
S8700 | 8710 / S8500
An instance of this MO (REM-OFF) is associated with every Remote Office box that is
administered on the switch. This MO monitors keep alive and periodic PING test failures, and if
these errors occur, they are logged against this MO.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: a PING test to the Remote Office has failed, and a MINOR alarm has been
raised.
The PING test verifies that a path to a registered Remote Office is good. When this error is
logged, as many as 26 endpoints (associated with that Remote Office) and several H.323
signaling groups could be out of service.
b. Error Type 257: A Keep-Alive Timer is set for every registered endpoint on the Remote
Office. The switch expects keep-alive update information within a certain time period. If that
time limit is exceeded, an error is logged. The error is a log-only error, because there is no
way to determine which entity has failed.
MO Name in
Alarm Log
Alarm
Level
Initial SAT Command to Run Full Name of MO
REM-OFF MIN ping node-name node-name |
ip-address location
Remote Office
REM-OFF WRN ping node-name node-name |
ip-address location
Remote Office
Table 713: Analog Line Error Log Entries
Error Type Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
1 (a) A ping test to an endpoint
failed.
MIN OFF ping node-name
node-name |
ip-address addr
257 (b
) A keep-alive update
request exceeded the time
limit for an endpoint.
Log only OFF ping node-name
node-name |
ip-address addr