DS1-FAC (DS1 Facility)
Issue 1 June 2005 1061
Clearing Firmware Errors
DS1 converter error reports are generated by firmware autonomously. DS1 converter error
reports are not associated with technician-demanded tests. The test board clear
command does not affect the error status known by the DS1 converter firmware. To clear every
on-board firmware-detected error unconditionally, use clear firmware-counters.
Error Log Entries and Test to Clear Values
Table 364: DS1 Facility Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
SAT Test to Clear Value
0 (a
)0Any AnyAnytest ds1-facility location sh r 1
1 (b
) Failure Audit #949 MAJ ON test board location sh r 1
18 (c
)0 busyout
ds1-facility
location
WRN OFF release ds1-facility location
257 (d
) Failure Audit #949 MIN ON test board location sh r 1
513 (e
) 1 Failure Audit #949 MIN OFF test board location sh r 1
513 (e
) 2 Failure Audit #949 MIN OFF test board location sh r 1
856 (f
) DS1 Facility Query for
Slips/Misframes #972
MIN OFF none
1025 (g
) Failure Audit #949 MAJ
1
1. These failures are logged as a WRN alarm when the error is first reported. The alarm severity is raised to a
MAJOR in 15 minutes if the problem persists.
OFF test board location sh r 1
1281 (h
) None Failure Audit #949 MAJ
1
OFF test board location sh r 1
1281 (h
) 1 Failure Audit #949 MAJ
1
OFF test board location sh r 1
1281 (h
) 2 Failure Audit #949 MAJ
1
OFF test board location sh r 1
1537 (i
) Failure Audit #949 MAJ
1
OFF test board location sh r 1
1793 (j
) Failure Audit #949 MAJ
1
OFF test board location sh r 1
2065 (k
) DS1 Facility Query for
Slips/Misframes #972
MIN OFF none
2305 (l
) Failure Audit #949 MAJ OFF test board location sh r 1
2561 (m
) Failure Audit #949 MIN
1
OFF test board location sh r 1