Communication Manager Maintenance-Object Repair Procedures
2380 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Incoming Dial Type tone,
rotary,
mf (to other Avaya systems only)
Wink Timer for wink type 300
Wink Timer for delay type 4500
Trunk Group screen, Page 3 (Administrable Timers)
Incoming Disconnect 100
Incoming Glare Guard 800ms or higher
Incoming Dial Guard 10
Incoming Incomplete Dial Alarm 25 or higher
Incoming Partial Dial 18
PPS 10 or 20
Make (for PPS 10) 35
Break (for PPS 10) 65
Make (for PPS 20) 15
Break (for PPS 20) 35
Outgoing Disconnect 100
Outgoing Glare Guard 800 or higher
Outgoing Rotary Dial Interdigit 800
Outgoing Seizure Response 5
Table 850: TN2242 administration (continued)
Field Value
2 of 2