ANL-LINE (8-Port Analog Line)
Issue 1 June 2005 421
Station Present Test (or Ringing Application Test) (#48)
This test provides a burst of ringing current to the terminal equipment and detects that current
flows. This test is to ascertain whether or not terminal equipment is connected to the port.
This test may cause some terminal equipment to ring briefly during daily maintenance. If this
ringing is disturbing the customer or the terminal equipment, it should be disabled using the
Tests field of the station administration screen. However, on some releases of the software, this
action disables Tests #6, 47, and 35, as well as Test #48.
PASS The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, by examining the station,
and by ensuring that the terminal is correctly translated as off-premises or
on-premises.
Note:
Note: This test always passes for circuit packs TN712 prior to
vintage 14 and TN742 prior to vintage 6.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Enter list config,
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the
port. If not, dispatch to verify that a valid board is inserted.
Table 123: Test #47 Loop Around and Conference Test (continued)
Error
Code
Test
Result
Description / Recommendation
5 of 5