Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1976 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Response to the test was not received from the C-LAN circuit pack within
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports on the board are idle (amber LED is off). Reset the circuit
pack by issuing busyout board location, reset board
location, and release board location.
2. If this result occurs again, replace the circuit pack.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT The necessary system resources to execute the test could not be
allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3times.
2800 ABRT No C-LAN in the same region.
1. Verify translations and retest.
2801 ABRT No IP address defined.
1. Verify translations and retest.
2802 ABRT Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
7
89
1007
FAIL PING to the destination failed through this port because the destination
was down.
1. Verify that at least one destination reachable through this port is “up”.
Once verified, execute test signaling-group grp# to verify that
the SIP Signaling Group Ping test (#1387) passes.
PASS PING through this port was successful.
Table 723: Test #1387 SIP Signaling Group Ping Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2