TIME-DAY (Time of Day)
S8700 | 8710 / S8500
The time of day contains the current year, month, day of the week, day of the month, hour,
minute, and second. The Time of Day MO monitors the time-of-day clock, and raises an alarm if
the time-of-day clock is not set or cannot be read by the software. If the time-of-day clock is not
set or cannot be read by the software, many features such as Time-of-Day Routing, CDR, ISDN
Call-by-Call, and duplication, are inoperative or incorrect. Use set time to set the time-of-day
clock when the system is initially powered up.
Use display time to read the time-of-day clock. Use set time to set the time-of-day clock.
The time-of-day clock has a backup battery to save the time of day during power failures.
Error Log Entries and Test to Clear Values
a. Error Type 247: software cannot read the time-of-day clock. During this condition, every
time stamp in Alarm Log entry, Hardware Error Log entry, and Software Error Log entry is
potentially inaccurate. In addition, any features that are sensitive to the time of day (such as
SMDR, Time-of-Day Routing, ISDN Call-by-Call) will not function correctly.
To resolve the alarm:
1. Use set time to set the time of day.
2. Use display time to display the time of day. If the time of day is displayed correctly,
wait 15 minutes and verify that the alarm is retired.
MO Name Alarm Level Initial SAT Command to Run Full Name of MO
TIME-DAY MIN set time Time of Day
Table 835: Time-of-Day Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 0 Any Any Any display time
247 (a
) 0 none MIN OFF set time