Communication Manager Maintenance-Object Repair Procedures
360 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
1004 ABRT The port was put in use during the test. The test has been aborted.
1. Use display port location to determine the voice port extension
of the port. Use status station to determine the service state of the
port. If the port is active, it is unavailable for certain tests. Refer to
“Status” commands in Maintenance SAT Commands
in Maintenance
Commands Reference (03-300191) for explanations of every possible
state. Wait until the port is idle before testing.
1020 ABRT Test disabled via background testing.
1. Use status station to determine when the voice port is available
for testing.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
1, 2 FAIL The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections. Failure code 1 indicates that the
Crosstalk test failed on the primary channel. Failure code 2 indicates that
the Crosstalk test failed on the secondary channel.
1. Replace the circuit pack (see caution at the beginning of this section).
PASS The port is using its allocated time slots correctly.
1. To verify that this is not an intermittent problem, repeat this test up to 10
times, and make sure it continues passing.
2. If complaints still exist, examine the connections.
Table 97: Test #9 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2