Communication Manager Maintenance-Object Repair Procedures
1698 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented. By clearing Error Codes associated with the Analog
Port Sanity test (#963), you may also clear errors generated from other tests in the sequence.
NPE Crosstalk Test (#9)
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected time slot and
never crosses over to time slots reserved for other connections.
One or more Network Processing Elements (NPE) reside on each circuit pack with a TDM-bus
interface. The NPE controls port connectivity, gain, and provides conferencing functions on a
per-port basis. If the NPE is not working correctly, one-way and/or noisy connections may be
observed. This test is part of a port’s long test sequence and takes approximately 10 to 20
seconds to complete.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
Analog Port Sanity test (#963) X X ND
Digital Loop-around test (#13) X X ND
NPE Crosstalk test (#9) X ND
Hook State Inquiry (#566) X X ND
Clear Error Counters (#270) X ND
Table 627: Test #9 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required to run this test are not available. The port may
be in use on a valid ATMS trunk test call.
1. Retry the command at 1-minute intervals up to 3 times.
1001 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.