Communication Manager Maintenance-Object Repair Procedures
2226 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one
test may also clear errors generated from other tests in the sequence.
Signaling Link State (#1251)
This test is nondestructive.
This test checks the current state of the signaling link. The test looks at the board-level
translations, checks that the board is physically inserted, gets the state of the D channel and
service state of the port.
The test passes if the signaling link (D channel) is connected and operating normally. The test
fails if the board is not installed, the signaling link is disconnected, or if the port is out of service.
The test aborts otherwise.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. Destructive; ND = Nondestructive
Signaling Link State Check test (#1251) X X ND
Service State Audit test (#256) X X ND
Call State Audit test (#257) X X ND
ISDN Test Call test (#258)
S8300 / G700: Aborts with Error Code 1412 on a G700.
XND
Table 797: Test #1251 Signaling Link State Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1018 ABRT The test is disabled.
1. Enable the test by entering enable test 1251.
1 of 2