Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
TBRI-PT (ISDN Trunk-Side BRI Port)
Issue 1 June 2005 2221
Layer 3 Query Test (#1243)
This test is nondestructive.
This test is used to check the application layer communications across the in-service ISDN D
channel. The test passes if a status inquiry message is successfully sent, fails if the signaling
link is down, and aborts if a query is already running or there is an internal error.
Table 794: Test #1243 Layer 3 Query
Error
Code
Test
Result
Description / Recommendation
1005 ABRT The test aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, a modem pool member or Music on Hold). This error
can be ignored.
1019 ABRT Test is already running.
1113 ABRT The signaling link is down.
1. Use test port location long to clear any errors which prevent
establishment of the signaling link.
2. Examine the results of Test #626, which is executed with the
command. If this test aborts or fails, follow the repair procedure for the
Signaling Link Status test.
3. Escalate problem if BRI Layer 3 Query test continues to abort.
1187 ABRT The circuit pack or port may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for TBRI-BD or
TBRI-PT.
a. If this Error Type is present for TBRI-PT, then release the port with
release port location and run the test again.
b. If the error is present for both TBRI-BD and TBRI-PT, then release
the circuit pack with release board location and run the test
again.
When you release the circuit pack, you release every port associated with it.
If certain ports still need to be busied out, use busyout port location
to busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2012 ABRT Internal system error
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
PASS The switch has successfully sent a Status Enquiry message.