Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ATM-EI (Expansion Interface Circuit Pack)
Issue 1 June 2005 569
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present or some
Tone Detectors may be out-of-service.
1. Resolve any TTR-LEV errors in the Error Log.
2. Resolve any TONE-PT errors in the Error Log.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1962 ABRT Every TALKER DSP is busy (an unlikely event).
1. Retry the command at 1-minute intervals up to 3 times.
2302 ABRT Inconsistent uplink message from the ATM-EI board. This is a very
unlikely event.
1. Retry the command at 1-minute intervals up to 3 times.
2752 ABRT The circuit pack in this location is not a TN230X.
1–8 None FAIL The board is writing to unauthorized TDM time slots. The error code
indicates the number of faulted TALKER DSPs.
1. Retry the command up to 3 times.
2. If the failure persists, replace the circuit pack.
1–8 PASS The board is not talking to unauthorized time slots on the TDM Bus. The
error code indicates the number of TALKER DSPs that were tested.
Table 184: ATM Crosstalk Test (#1298) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2