Communication Manager Maintenance-Object Repair Procedures
390 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correctly perform the
conferencing function.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Enter list config,
and resolve any problems.
2. If the board was found to be correctly inserted in step 1, enter
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the
port. If not, verify that a valid board is inserted.
Table 113: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 4
Table 114: Test #7 Conference Circuit Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call. This result is also reported for the system’s
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port location to determine the station’s extension.
Enter status station extension to determine the service state of
the port. If the port is active, wait until it is idle.
2. Retry the command at 1-minute intervals up to 5 times.
1 of 3