Communication Manager Maintenance-Object Repair Procedures
2358 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 843: Test #40 Tone Generator Transmission Test
Error
Code
Test
Result
Description / Recommendation
None ABRT The system was not able to allocate all the resources needed for this
test or there was an Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1 ABRT The system could not allocate all the resources needed to test the
DTMF tones.
1. Retry the command at 1-minute intervals up to 5 times.
1001 ABRT The system was not able to put the tone generation facility in the
appropriate mode to test it.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test connection. This
can happen when the system is heavily loaded. If the system is not
heavily loaded, use test tdm port-network P to test the TDM
bus.
1. Retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test connection.
This can happen when the system is heavily loaded or there is not an
IPSI or Tone Detector circuit pack in the port network where this test is
being executed.
1. Make sure there is an IPSI or Tone Detector circuit pack in the
same port network.
2. If the circuit pack is missing, install one in the same port network.
3. Allow approximately 1-minute for Tone Detector maintenance to
run on the newly inserted IPSI or Tone Detector circuit pack.
4. Retry the command at 1-minute intervals up to 5 times.
1022 ABRT Tone detection for the system is administered as wide broadband (tone
detection mode 5), and the Tone Detector used for this test was not a
TN420C (the only circuit pack with this capability). GPTD ports on other
types of Tone Detector circuit packs are taken out of service since they
cannot provide the administered function. Either:
● Change the tone-detection mode administered on the
system-parameters country-options screen.
● Remove all non-TN420C circuit packs from the system.
1 of 2