DID-DS1 (Direct Inward Dial Trunk)
Issue 1 June 2005 887
Error Log Entries and Test to Clear Values
Table 303: DID-DS1 Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
) 0 Any Any Any test trunk grp#/mem#
1 (b
)Any
15 (c
) Any Port Audit and
Update test (#36)
18 (d
)WRNOFFrelease trunk grp#/
mem#
130 (e
) None WRN ON test trunk grp#/mem#
257 (f
) 57474
57473
513 (g
) 57392 MAJ
MIN
1
1. This alarm is raised only when the Base Tone Generator field is 4 (Italy) on the System-Parameter
Country screen. This alarm is a MINOR alarm unless 75% or more trunks in this trunk group are out of
service, when the alarm is upgraded to a MAJOR alarm.
769 (h) 57393 MAJ
MIN
1
1281 Conference Circuit
test (#7)
MIN
WRN
2
2. Major alarms may be downgraded to Warning alarms based on the value used in set options.
ON test trunk grp#/mem#
l r 4
1537 NPE Crosstalk test
(#6)
MIN
WRN
2
ON test trunk grp#/mem#
l r 3
1793 (i
) test board location l
2305 (j
) 50944 None MAJ
MIN
1
OFF
3840 (k
) Port Audit and
Update test (#36)