Communication Manager Maintenance-Object Repair Procedures
2372 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
4. Enter display alarms and determine the location of the circuit pack with the alarmed
GPTD-PT, DTMR-PT, or GPTD-PT.
Run test board location l r 3 for that circuit pack.
If this does not clear the TTR Level alarm, replace the Tone Detector or Call Classifier circuit
pack with the alarmed GPTD-PT, DTMR-PT, or CLSFY-PT.
Error Log Entries and Test to Clear Values
!
WARNING:
WARNING: The Alarm is upgraded to MAJOR if the Base Tone Generator is set to 12
(France).
Notes:
a. Error Type 1: does not indicate a current error condition. It indicates that the number of
DTMR ports in service was below the administered threshold, but is now equal to or greater
than the threshold. These errors are typically generated during boot time or other
transitional states when the ports are being brought into service.
b. Error Type 2: the total number of DTMR ports currently in service is below the administered
threshold. To clear the alarm, see Repair Procedure for TTR-LEV
on page 2371.
c. Error Type 3: does not indicate a current error condition. It indicates that the number of
GPTD ports in service was below the administered threshold, but is now equal to or greater
Table 849: TTR Level Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
1 (a
) 1 None
2 (b
) 2 WRN
(See message below)
OFF
3 (c
) 3 None
4 (d
)4 WRN OFF
5 (e
) 5 None
6 (f
)6 WRN OFF
7 (g
)7 MAJ OFF
8 (h
)8 MIN OFF
9 (i
)9 MIN OFF