Communication Manager Maintenance-Object Repair Procedures
2314 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Audit Update Test (#36)
This test sends to the circuit pack updates of translations for every administered port on the
circuit pack. It is non-disruptive and guards against possible corruption of translation data
contained on the circuit pack. No response is expected from the circuit pack. Port translation
data includes:
Start type: immediate, automatic, wink-start, or delay dial
Rotary or DTMF senderization in or out
Disconnect timing: 10 to 2550 ms in 10-ms increments
DMTF time slot
Continuous-seize-ack (TN2140)
PASS Tie trunk Looparound and Conference test is successful. This port is
functioning properly.
1. If users are reporting troubles, examine loop connections to the port.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board, if
necessary.
2. Enter busyout board location.
3. Enter reset board location.
4. Enter release board location.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
Table 830: Test #33 Looparound and Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
4 of 4
Table 831: Test #36 Audit Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2