Communication Manager Maintenance-Object Repair Procedures
362 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1004 ABRT The port was put in use during the test. The test has been aborted.
1. Use display port location to determine the voice port extension
of the port. Use status station to determine the service state of the
port. If the port is active, wait until it is idle before retesting.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
7 FAIL Conference test failed on the primary channel. In some cases, users may not
notice a disruption in service. In extreme cases, the conferencing feature may
not work at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
15 FAIL The control channel between the processor and AUDIX is not transmitting
properly. User impact may range from no noticeable effect to loss of use of
this port. This failure could also be disruptive to other users.
16 FAIL The secondary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
None FAIL The test failed for reasons external to the AUDIX.
1. Run circuit tests to check the Tone Generator circuit and the Tone
Detector circuit using test board location s.
2. Resolve any problems detected on the Tone Generator circuit or Tone
Detector circuit.
3. If both circuit packs are functioning properly and the test still fails,
replace the AUDIX (see caution at the beginning of this section).
PASS Voice and Control Channel Local Loop test passed. Every channel are
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to
10 times, and see whether it continues to pass.
2. If complaints still exist, examine the connections.
Table 98: Test #13 Voice and Control Channel Local Loop Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2