TBRI-BD (TN2185 ISDN Trunk-Side BRI)
Issue 1 June 2005 2195
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: the circuit pack stopped functioning or was physically removed from the
system.
Note:
Note: This alarm logs approximately 11 minutes after removing the circuit pack and/or
the SAKI Sanity test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot as the error
indicates. See note (h) for additional information.
c. Error Type 257: transient communication problems between the switch and this circuit
pack. Execute test board location and refer to the repair procedures for the Control
Channel Loop-Around Test (#52) on page 2512.
1537 (i) 46082 MIN ON
1793 (j
) 46080 MIN ON
1794 (j
) 46094 MIN ON
1795 (j
) 46085 MIN ON
2305 (k
) 46104 None ON
2306 (k
) 46081 None ON
3330 (k
) 46083 MIN OFF
3586 (l
)MINOFF
3841 (m
) 4096 -
4101
3842 (n
) 46095
3843 (o
) 46097
Table 783: TBRI-BD Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2