Communication Manager Maintenance-Object Repair Procedures
1894 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: SCOTCH Synchronous Loop-around test (#1275) failed.
1. Test the port (test port location long).
2. See SCOTCH Synchronous Loop-Around Test (#1275)
on page 1898 for repair
procedures.
c. Error Type 257: C-LAN port detected overrun or underrun condition that may indicate a
hardware problem.
1. Test for hardware problem (test port location long).
Table 691: PPP-PT Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test port location s
1 (b
) 0 SCOTCH Sync
Loop- Around
(#1275)
MIN ON test port location l r 3
257 (c
)0 WRNOFF
513 (d
)0 MINOFF
769 (e
)0 WRNOFF
1281 (f
)0
1537-8 (g
)See
note
Session Status
test (#1286)
MIN OFF
1793–
1920 (h
)
See
note
2305–
2816 (i
)
See
note
3329 (j
) 35768 TCP/IP Ping test
(#1281)
WRN OFF
3585 (k
) 0, 1 TDM Loop-Around
(#1285)
MAJ ON test port location l r 3