CO-TRK (Analog CO Trunk)
Issue 1 June 2005 835
CO-TRK (Analog CO Trunk)
S8700 | 8710 / S8500 / S8300
S8700 | 8710 / S8500
For systems supporting circuit packs:
If ATMS testing is enabled, check the error log for ATMS errors 3840 and 3841. If the error log
indicates that measurements exceeded acceptable thresholds, and no other trouble is found
with test trunk, run the ATMS test call with test analog-testcall port location
full.
Note:
Note: Many trunk problems are caused by incorrect settings of parameters on the trunk
group administration screen. Settings must be compatible with the local
environment and with parameter settings on the far end.
Analog CO trunks are 2-wire analog lines to the CO that support both incoming and outgoing
calls. CO trunk circuit packs have eight ports, each of which provides an interface between the
2-wire CO line and the 4-wire TDM bus. The system supports the following CO trunk circuit
packs:
MO Name in Alarm Log Alarm
Level
Initial Command to Run Full Name of MO
CO-TRK MAJ
1
1. A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by set
options and that at least 75% of the trunks in this trunk group are alarmed.
test port location Analog CO Trunk
CO-TRK MIN test port location Analog CO Trunk
CO-TRK WRN test port location Analog CO Trunk
TN438 TN2138
TN447 TN2147
TN465 TN2148
TN747