Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
372 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
b. Error type 769 is a log only error and is displayed when Communication Manager does not
receive a response from the AESVCS Server to a heartbeat message that was sent over
the AESVCS Link. Failure to receive a response to a heartbeat message results in the
deletion of the AESVCS Link by Communication Manager. Both an AESVCS Session Level
and Link level error is generated against this condition. Escalate if the error persists.
c. Error type 1537 is a log only error and displayed when an AESVCS Link is deleted from an
AESVCS Session for reasons other than a heartbeat failure. Both an AESVCS Session
Level and Link level error is generated against this condition. The Aux Data field contains
the reason code.
Aux Data Description
1 The far end closed the socket connection. Check the error logs on
the AEVCS Server for more information.
100 The reset aecvcs-link command was used to close the socket
connection
101 The AESVCS Interface on the IP Services form was disabled.
102 The AESVCS Interface was removed from the IP Services form.
103 The AE Services Server was disabled on the AE Services
Administration page of the IP Services form.
104 The AE Services Server was deleted on the AE Services
Administration page of the IP Services form.
200 The socket connection closed due to an internal error. Escalate if the
problem persists.
201 The socket connection was unexpectedly closed by Communication
Manager. Escalate if the problem persists.
202 Communication Manager detected and error and closed the socket
connection. Escalate if the problem persists.
203 Communication Manager detected an error reading from the socket
and closed the connection. Escalate if the problem persists.
204 Communication Manager failed to write a complete message and
closed the socket connection. Escalate if the problem persists.
205 AE Server established a new connection causing Communication
Manager to close the existing one. Escalate if the problem persists.
206 Communication Manager failed to send a heartbeat request and
closed the socket connection. Escalate if the problem persists.
207 Communication Manager detected a protocol violation and closed
the socket connection. Escalate if the problem persists.
1 of 2