Communication Manager Maintenance-Object Repair Procedures
864 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
If the Error Type is greater than 1000, subtract 1000 from the Error Type field before
consulting the table.
S8700 MC:Before proceeding, if multiple CONFIG errors are simultaneously logged with an
Aux Data of 1, investigate any EXP-INTF (Expansion Interface) errors.
Once the port’s circuit-pack location has been determined from Table 295: Converting Error
Types To Carrier Locations on page 864, use list configuration all to determine
whether the circuit pack is inserted. If the circuit pack has already been inserted but the
error persists, replace the circuit pack. If not, insert the pack.
Table 295: Converting Error Types To Carrier Locations
Error Type Carrier Location
1(a
)
2E01
3E02
4E03
5E04
6E05
7E06
8E07
9E08
10 E09
11 E10
12 E11
13 E12
14 E13
15 E14
16 E15
17 E16
18 E17
19 E18
20 E19
21 E20
1 of 5