Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1130 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1002 ABRT The system could not allocate time slots for the test. The system is under
heavy traffic conditions or it has time slots out of service due to TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, repeat test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of Tone Detectors present, or some
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was seized by a valid call during the test.
1. Use display port location to determine the station extension or
attendant number of the port.
2. Use status station or status attendant to determine the
service state of the port. If the port is in use, wait until it is idle before
retesting. Attendants are always in use (off-hook) if the handset is
plugged in and the port is not busied out.
3. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Rerun the test at 1-minute intervals up to 5 times.
Table 384: Test #13 Voice and Control Channel Local Loop Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3