EXP-PN (Expansion Port Network)
Issue 1 June 2005 1237
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: informational entry only, indicating that a PN Reset Level 1 (PN Warm
Restart) has been executed on this PN.
b. Error Type 257: informational entry only, indicating that a PN Reset Level 2 (PN Cold
Restart) has been executed on this PN. This does not include restarts done at system
initialization time.
c. Error Type 513: indicates that a PN is not in service when it is expected to be. The value
specified in the port field of the error log, is the PN number of the affected PN. When this
condition occurs, examine every system link error and EXP-INTF or ATM-PNC error to aid
in resolving the alarm (examples of system link errors are errors logged against PKT-INTF,
EXP-INTF, SNI-BD, FIBER-LK, and PKT-BUS and for ATM, PKT-BUS, ATM-EI,
ATM-NTWK). Also check that all fiber connectivity matches that have been administered for
the system. This alarm and error is resolved and removed from the logs only when the PN
comes back into service.
d. Error Type 769: This alarm is raised when PN maintenance has attempted to execute a
Cold Restart recovery action two times, and both restarts failed. This will cause the PN to be
placed in Emergency Transfer. Examine every EXP-INTF or ATM-EI error that, when
cleared, may aid in resolving this alarm. Also check for any SNI-BD, SNI-PEER, FIBR-LK,
SN-CONF, or DS1C-BD errors or for ATM, ATM-EI or ATM-NTWK errors that may indicate a
communication problem between the processor and the PN. Make sure that the physical
fiber connectivity matches that of system administration.
e. Error Type 1025: If two cabinets are DS1-C connected and their companding modes differ,
the system raises a major alarm only if the Multinational Locations field is y on the
Customer Options form. See Administrator Guide for Avaya Communication Manager,
03-300509 for more information about administering multiple locations, particularly the
Locations form in Screen Reference section.
Table 418: Expansion Port Network (EXP-PN) Error Log Entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear
Value
1 (a
) 0 None None
257 (b
) 0 None None
513 (c
)0 None MAJ OFF
769 (d
)0 None MAJ OFF
1025 (e
) Any None MAJ OFF