AN-LN-PT (Analog Line Port)
Issue 1 June 2005 435
Battery Feed Test (or Port Diagnostic Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling, rotary dial pulsing,
transmission, and balance. This test checks the signaling and switchhook capabilities of the
battery feed chip by terminating the port, applying battery power, and detecting the resulting
current.
Table 128: Test #35 Battery Feed Test
Error
Code
Test
Result
Description / Recommendation
ABRT Necessary system resources could not be allocated to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1000 ABRT System resources are unavailable. The port may be busy with a valid call.
This result is also reported for the system’s Music-On-Hold port when it is
off-hook, which it usually is.
1. Enter display port location to determine the station’s
extension.
2. Enter status station extension to determine the service state of
the port.
3. If the port is active, wait until it is idle. Retry the command at 1-minute
intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABRT A valid call seized the port during the test and aborted the test.
1. Use display port location to determine the station extension.
2. Use status station extension to determine the service state of
the port.
3. If the port is active, wait until it is idle before testing. Retry the
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABRT This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
1 of 3