1568 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1000 ABRT System resources required to run this test are not available. The port
may be busy with a valid call.
1. Use display port location to determine the station extension
of the port. Use status station to determine the service state of
the port. If the port is in use, wait until the port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension
of the port. Use status station to determine the service state of
the port. If the port is in use, wait until the port is idle before testing.
The battery feed circuitry is tested for proper battery voltage by testing
the switchhook state. In response to the test message, the on-board
firmware terminates the line and checks for switch-hook presence. The
termination is then removed, and a check is made for no switch-hook
presence. The MET set must be on-hook for the test to execute.
1. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1018 ABRT Test disabled by software patch.
2000 ABRT This port may have been busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port.
If this error type is present, then release the port using release
station extension and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Table 579: Test #35 Port Diagnostic Test (continued)
Error
Code
Test
Result
Description / Recommendation