IPMEDPRO (TN2302 IP Media Processor)
Issue 1 June 2005 1375
2801 ABRT The IP Media Processor board has not been administered on the
ip-interfaces form.
2806 ABRT The system could not find any in-service IP Media Processor boards to use
as a destination for this test.
2807 ABRT The specified IP Media Processor board has been disabled on the
ip-interfaces screen.
10XX
XX = PN #
FAIL The test tone was not successfully sent from the IP Media Processor
specified in the test command, and not successfully received by an IP
Media Processor in the PN specified in the error code (XX). Source to
destination direction failed. Destination to source direction not tested.
XX = PN number.
1. Resolve all other board alarms for the specified source IP Media
Processor.
2. Resolve all other board alarms for the IP Media Processor boards in
the destination PN.
3. Use ping and traceroute to localize the problem to the customer’s
LAN/WAN IP network.
20XX
FAIL The test tone was successfully sent from the IP Media Processor specified
in the test command and received by an IP Media Processor in the PN
specified in the error code (XX).
The test tone was not successfully sent in the reverse direction.
Destination to source direction failed. Source to destination direction
passed.
1. Resolve all other board alarms for the specified source IP Media
Processor.
2. Resolve all other board alarms for the IP Media Processor boards in
the destination PN.
3. Use ping and traceroute to localize the problem to the
customer’s LAN/WAN IP network.
PASS The customer network is functioning properly. The test tone was
transmitted and received successfully between:
● The IP Media Processor specified in the test command
● Every other IP Media Processor in the set of connected IP network
regions.
Table 483: Long IP 2-Way Transmission Test (#1506) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3